SRPM24
RW: Read write. Enables requests accompanied by this community string to display MIB-object
information and to set MIB objects.
Click
Add
button.
To remove the community string, select the community string that you have defined and
click
Remove
button. You cannot edit the name of the default community string set.
Trap Manager:
A trap manager is a management station that receives the trap messages generated by the Device. If no
trap manager is defined, no traps will be issued. Create a trap manager by entering the IP address of the
station and a community string. To define a management station as a trap manager, assign an IP address,
enter the SNMP community strings, and select the SNMP trap version.
IP Address: Enter the IP address of the trap manager.
Community: Enter the community string.
Trap Version: Select the SNMP trap version type—v1 or v2c.
Click
Add
button.
To remove the community string, select the community string listed in the current managers field
and click
Remove
button.
There are three types of trap:
Standard: Includes DHCP Setting, Authentication Failure, and Cold Start.
Power over Ethernet: Includes DC disconnect, PD disconnect, Overload, Short Circuit, Over
Temperature, Port off by Power Management.
UPS: Includes Power Disconnect, Power Fault, Battery Low, and Power Over Temperature.
[Note]
Power over Ethernet traps also record in System Log and E-mail Alert.
Email Alert
You can set up the mail server IP, mail account, password, and forwarded email account for receiving the
event alert.
Email Alert: Enable or disable the email alert function.
SMTP Server IP: Assign the mail server IP address (when Email Alert enabled, this function will
then be available).
Sender: Type in an alias of the device in complete email address format, e.g. [email protected],
to identify where the event log comes from.
36