Rack-mounted installation – Amer Networks SRPM24 User Manual
Page 13

SRPM24
Rack-mounted Installation
The switch comes with a rack-mounted kit and can be mounted in an EIA standard size, 19-inch Rack.
The Device can be placed in a wiring closet with other equipment.
Perform the following steps to rack-mount the device:
A.
Position one plate to align with the holes on one side of the device and secure it with the smaller
plate screws. Then attach the remaining plate to the other side of the Device.
Attach mounting plates with screws
B.
After attaching both mounting plates, position the switch in the rack by lining up the holes in the
plates with the appropriate holes on the rack. Secure the Device to the rack with a screwdriver and
the rack-mounting screws.
Mount the 24-port managed PoE Midspan switch in an EIA standard 19-inch Rack
Note: For proper ventilation, allows about at least 4 inches (10 cm) of clearance on the front and 3.4
inches (8 cm) on the back of the Device. This is especially important for enclosed rack installation.
12