Table 1-1, Product matrix -14, Hazardous area oxymitter 4000 – Emerson Process Management OXYMITTER 4000 User Manual
Page 44: Instruction manual

Instruction Manual
IB-106-340C Rev. 4.1
July 2004
1-14 Description and Specifications
Rosemount Analytical Inc. A Division of Emerson Process Management
Hazardous Area Oxymitter 4000
Table 1-1. Product Matrix
OXT4C
OXYMITTER 4000 - EXPLOSION PROOF - IN SITU OXYGEN TRANSMITTER
Explosion Proof Oxygen Transmitter - Instruction Book
Code
Sensing Probe Type with Flame Arrestor
1
Ceramic Diffusion Element Probe (ANSI 3 in. 150 lbs)
2
Snubber Diffusion Element (ANSI 3 in. 150 lbs)
3
Ceramic Diffusion Element Probe (DIN 2527) - 1/4 in. Tube Fittings
4
Snubber Diffusion Element (DIN 2527) - 1/4 in. Tube Fittings
5
Ceramic Diffusion Element Probe (JIS)
6
Snubber Diffusion Element (JIS)
7
Ceramic Diffusion Element (ANSI 3 in. 300 lbs)
8
Ceramic Diffusion Element (ANSI 4 in. 300 lbs)
Code
Probe Assembly
0
18 in. (457 mm) Probe
1
18 in. (457 mm) Probe with 3 ft (0.91 m) Bypass
2
18 in. (457 mm) Probe with Abrasive Shield
(1)
3
3 ft (0.91 m) Probe
4
3 ft (0.91 m) Probe with Abrasive Shield
(1)
5
6 ft (1.83 m) Probe
6
6 ft (1.83 m) Probe with Abrasive Shield
(1)
Code
Mounting Adapter - Stack Side
0
No Adapter Plate (“0” must be chosen under “Mounting Adapter - Probe Side” below)
1
New Installation - Square weld plate with studs
2
Model 218 Mounting Plate (with Model 218 Shield Removed)
3
Competitor’s Mount
(2)
Code
Mounting Adapter - Probe Side
0
No Adapter Plate
1
Probe Only (ANSI)
2
New Bypass or New Abrasive Shield (ANSI)
4
Probe Only (DIN)
5
New Bypass or New Abrasive Shield (DIN)
7
Probe Only (JIS)
8
New Bypass or New Abrasive Shield (JIS)
Code
Electronic Housing and Filtered Customer Termination - NEMA 4X, IP66
11
HART
®
Integral Electronics, Standard Filtered Termination,
ATEX Certification
12
HART
®
Integral Electronics, Transient Protected Filtered Termination,
ATEX Certification
13
HART
®
Remote Electronics (requires cable), Standard Filtered Termination,
ATEX Certification
14
HART
®
Remote Electronics (requires cable), Transient Protected Termination,
ATEX Certification
21
HART
®
Integral Electronics, Standard Filtered Termination,
CSA/FM Certification
22
HART
®
Integral Electronics, Transient Protected Termination,
CSA/FM Certification
23
HART
®
Remote Electronics (requires cable), Standard Filtered Termination,
CSA/FM Certification
24
HART
®
Remote Electronics (requires cable), Transient Protected Termination,
CSA/FM Certification
OXT4C
3
3
1
1
11
Example