0x1ef00), Proprietary: received pgn source – Airmar PB200 User Manual
Page 36

PB200 WeatherStation User Manual revision 1.000
Proprietary and Confidential
30
NMEA 2000® TRANSMITTED PARAMETER GROUP
PGN
126720-47
(0x1EF00)
Proprietary: Received PGN Source
Single Frame: No
Priority: 7/Y/N
Update Rate: 0/N/N
Destination: Address
Query Support: Yes
Access Level: 0
Field
#
Name
Request
Param. DD
DF
Type Resolution
Value
Remark
1 Manufacturer Code
Yes
DD172 DF52 11 bits
1
135 (decimal)
Manufacturer Code for Airmar
Technology.
2 Reserved bits
No
DD001 DF52 2 bits
1
0x3
All bits set to logic "1"
3 Industry Group
Yes
DD168 DF52 3 bits
1
4 (decimal)
Industry Group for "Marine
Industry".
4 Proprietary ID (PID)
Yes
DD005 DF53 uint8
1 bit
47 (decimal)
47 = Received PGN Source
5 Received PGN number
Yes
DD009 DF52 24 bits
1
128259 only (for PB200)
24-bit Parameter Group Number
(PGN) expressed in binary, LSB is
transmitted first.
6 Rule
No
DD003 DF52 3 bits
1
0 = Reserved
1 = Highest priority Airmar device
2 = Highest priority device, any mfr.
3 = Specific device
4 = Specific device, or highest priority
5-6 = Reserved
7 = No action/Data Not Available
The default value for this field is 1.
This field is saved in EEPROM.
See the text below for an
explanation of this field.
7 Reserved bits
No
DD001 DF52 5 bits
1
0x1F
All bits set to logic "1"
8 CAN name
No
N/A DF52 64 bits
1
Variable
CAN name for the specific
transmitting device intended to
provide the PGN specified in field
5. The CAN name is supplied by
the address claim PGN 60928 of the
transmitting device. This field is
saved in EEPROM.