4 if the drive motor burns out or blows fuses – AEC OFE Blender User Manual
Page 36

OFE Series Weight Loss Feeders
Page 35
; Check to see that the additive pellets are feeding consistently out of the weigh
hopper and not bridging occasionally in the hopper discharge throat. Consult the 
factory if this is the case. We do offer a larger opening hopper (up to 2
1
/
2
inches). The feeder is designed for virgin pellet color concentrate. IT IS NOT 
DESIGNED FOR REGRIND MATERIALS. 
; Check the extruder screw speed pick-up proximity switch to ensure that it is
reading the extruder screw revolutions accurately.
7-4 If the Drive Motor Burns Out or Blows Fuses
; Check motor speed. Unit is probably running too slow. Change gear reducer to
higher ratio unit.
; Check auger to housing clearance, and if pellets are binding auger, consult
factory. Check auger for straightness. Sometimes the operators will let the drive 
hang off the auger without removing it fully from the housing. This will bend 
the auger. Bent augers are not covered under warranty. 
; Check input voltage and wiring size to see if a low voltage situation exists.
Quite often the feeder and 110V loading systems are wired into the same outlet. 
The voltage will check out at 120V when there is no load. Check the voltage 
when all the units are operating at the same time. It will sometimes drop 20 
percent or more. This indicates that the wire size to the outlet is too small to 
carry the load required. This condition will normally show up first on the 
loading system motors. 
; Check the extruder screw speed pick-up proximity switch to ensure that it is
reading the extruder screw revolutions accurately.