OFE Series Weight Loss Feeders
Page 33
6-6 Pneumatic System Maintenance
The OFE Feeder uses plant-supplied compressed air to operate the reload valve on the
surge hopper.
It is the user’s responsibility to provide CLEAN AND DRY air. The air supply should be
filtered through a 5 micron air filter and have a water separator installed. Oil should not
be used unless air dryers are installed on the compressed air supply.
Important!
Dirty air can affect accuracy, result in poor performance
and cause injury. Provide a 5-micron air filter on the air
supply to the blender and be sure excess oil is removed.
5 MICRON
FILTER
DRY 60 psi COMPRESSED AIR
LUBRICATOR
PRES SURE
REGULATOR
OS/OA BLENDER
CUSTOMER-SUPPLIED COMPRESSED AIR COMPONENTS
AEC provides all pneumatic lines on the feeder piped to a single ¼” NPT standard pipe
thread fitting.
OFE FEEDER