beautypg.com

Westermo TD-34 User Manual

Page 59

background image

59

6610-2203

13. Schneider PLC application

TD-34 #1

PC – IBM-compability

#1

V.32b

#4

V.32b

RS-232

9600 bit/s,

8O1

RS-485

9600 bit/s,

8O1

TD-34 #2

PSTN

Equipment:
2 pcs TD-34, PSTN simulator, PC with PLC program (Schneider PL7 Pro V4.1),
Schneider PLC (TSX Micro), power supplies.

Switch settings:

TD-34 #1

TD-34 #2

Note

SW1

2, 3, 5, 7 ON

2, 3, 5, 7 ON

9600 bit/s, 8O1 format

SW2

All OFF

5, 7 ON

SW3

4 ON

4 ON

PSTN ITU-T V.32b modulation

SW4

3, 5, (8) ON

(8) ON

AT commands:
TD-34

#1 ATE0V1X3%C0%E0&D0&K0&Y1&W0

TD-34

#2 ATE0V1X3%C0%E0&D0&K0&Y1&W0

PL7 Pro V4.1

ATE0V1X3%C0%E0&D0&K0&Y1D4

Application:
Step 1:

Configuration

Set switches on TD-34 #1 and #2
Start PLC program (chneider PL7 Pro V4.1)
Configure PLC program (please refer to manual)
Power On PLC (Schneider TSX Micro)
Power On TD-34 #1 and #2

Step 2:

Application

Run PLC program (please refer to manual)
...

This manual is related to the following products: