\N – Operating Mode
This command controls the preferred error correcting mode to be negotiated in a
subsequent data connection.
\N0 Selects normal speed buffered mode (disables error-correction mode). (Forces &Q6.)
\N1 Serial interface selected – Selects direct mode and is equivalent to &Q0 mode of
operation. (Forces &Q0.)
\N2 Selects reliable (error-correction) mode.The modem will first attempt a LAPM
connection and then an MNP connection. Failure to make a reliable connection
results in the modem hanging up. (Forces &Q5, S36=4, and S48=7.)
\N3 Selects auto reliable mode.This operates the same as \N2 except failure to make a
reliable connection results in the modem falling back to the speed buffered normal
mode. (Forces &Q5, S36=7, and S48=7.)
\N4 Selects LAPM error-correction mode. Failure to make an LAPM error-correction
connection results in the modem hanging up. (Forces &Q5 and S48=0.)
Note:The -K1 command can override the \N4 command.
\N5 Selects MNP error-correction mode. Failure to make an MNP error-correction
connection results in the modem hanging up. (Forces &Q5, S36=4, and S48=128.)
O – Online
This command determines how the modem will enter the on-line data mode. If the modem is
in the on-line command mode, it enters the on-line data mode with or without a retrain.
If the modem is in the off-line command mode (no connection), ERROR is reported.
Syntax:
ATO
= 0
Enters on-line mode without retrain (Default)
= 1
Enters on-line mode with retrain
Examples:
Result Codes: OK
ERROR
Otherwise
*P – Store Password and Callback number
It is possible to store 2 different Passwords and Callback numbers in the modem.
This command works if command *G1 is used.
The command format is:
*P0:Password#0:Callbacknumber#0
*P1:Password#1:Callbacknumber#1
Password min. 6 characters max. 12 characters.
Callback number up to 18 characters.
If Password and Callback number is stored then the modem prompts the text ”PASSWORD:”
before releasing the connection and dialing back after a time given in S13.
If target is busy three retries will be executed.
If no Callback number is stored then the modem prompts the text ”PASSWORD:”
before switching into normal data transmission mode.
If no Password is stored then the modem prompts ”CALLBACK NUMBER:” before releasing
the connection and dialing back after a time given in S13.