Westermo TD-34 User Manual
Page 38

38
6610-2203
*WIOL – General IO list
This command set IO list entries with parameters and data.
Syntax:
AT*WIOL=
AT*WIOL=?
AT*WIOL?
IO entry number
IO entry service(0=NONE, 1=DIAL, 2=SMS, 3=TEXT,
4=EMAIL, 5=OUT, 6=CMD, 7=TRANS)
IO retry
(0=NO, 1=RETRY, 2=RETRY_3, 3=NEXT_OK,
4=NEXT_ERR)
IO timeout (0=NO, 1-255=MINUTES)
IO timeout (0=NO, 1=PRIORITY)
IO entry data field 1
IO entry data field 2
Examples:
AT*WIOL =1,2,2,0,12345,ABCDEFG
OK
AT*WIOL?
# SERVICE
FLAG
TIME
PRI
DATA1
DATA2
1 DIAL
NO
000
0
12345
2 SMS
RETRY_3 000
1
12345
3 NONE
NO
000
0
4 NONE
NO
000
0
5 NONE
NO
000
0
6 NONE
NO
000
0
7 TEXT
RETRY
005
1
123
ABC
8 NONE
NO
000
0
OK
AT*WIOL=?
*WIOL : (1-8),(0-7),(0-4),(0-255),(0,1),(0-16 CHAR), (0-40 CHAR),
OK
Result Codes: OK
(0-16 Characters) ,(0-40 Characters)
ERROR
Otherwise