7. DAILY USE
7.1 Used as a dispenser
Switch on MC12 and press
Program example with PD12 as a filler:
Volume: 8.5 ml.
Tube diameter: 3.2.
Velocity: 400 rpm.
Acceleration: 35.
Small back suction.
100 fillings to be completed.
An interval of 1.1 seconds between the fillings.
specific gravity for instance, water
The above job shall be programmed as follows:
Volume:
<1>+
Tube diameter: <2>+
Velocity:
<3>+
Acceleration:
<4>+
Back suction:
<5>+
Batch size
(Number of fillings): <6>+
Delay (intervals): <7>+
Specific gravity
<9>+
You have now programmed MC12 for the job, but want to reset the built-in counters. In function 8
the counter indicates "number of completed fillings" and in function 11 "accumulated volume".
Completed fills: <8>+
Acc. volume: <11>+
Inform MC12 that you want fillings by pressing
Every time
carry out 100 fillings of 8.5 ml at an interval of 1.1 seconds between each filling.
Press
Press Arrow Down twice, and on the status lines display show that F8: and F11: are counting
each filling.
F10: gives a current indication of the number of fillings completed per minute.