beautypg.com

Operators and reference manual mc12, Daily use – Watson-Marlow MC12 User Manual

Page 36

background image

Operators and Reference Manual

MC12

MC12 OM RM 1.03_EN

Version: 1.03

Date: 2010-11-17

Page 36 of 46

7. DAILY USE

7.1 Used as a dispenser


Switch on MC12 and press twice.

Program example with PD12 as a filler:

Volume: 8.5 ml.
Tube diameter: 3.2.
Velocity: 400 rpm.
Acceleration: 35.
Small back suction.
100 fillings to be completed.
An interval of 1.1 seconds between the fillings.
specific gravity for instance, water

The above job shall be programmed as follows:

Volume:

<1>++<8>+<.>+<5>+

Tube diameter: <2>++<3>+<.>+<2>+
Velocity:

<3>++<4>+<0>+<0>+

Acceleration:

<4>++<3>+<5>+

Back suction:

<5>++<1>+

Batch size
(Number of fillings): <6>++<1>+<0>+<0>+
Delay (intervals): <7>++<1>+<.>+<1>+
Specific gravity

<9>++<1>+<.>+<0>+


You have now programmed MC12 for the job, but want to reset the built-in counters. In function 8
the counter indicates "number of completed fillings" and in function 11 "accumulated volume".

Completed fills: <8>+++
Acc. volume: <11>+++

Inform MC12 that you want fillings by pressing .
Every time or the foot switch is pressed, or every time an electric signal is given, the filler
carry out 100 fillings of 8.5 ml at an interval of 1.1 seconds between each filling.

Press , verify that the filler starts and let it run.
Press Arrow Down twice, and on the status lines display show that F8: and F11: are counting
each filling.
F10: gives a current indication of the number of fillings completed per minute.