beautypg.com

Operators and reference manual mc12 – Watson-Marlow MC12 User Manual

Page 34

background image

Operators and Reference Manual

MC12

MC12 OM RM 1.03_EN

Version: 1.03

Date: 2010-11-17

Page 34 of 46


Passwords must consist of 4 digits and be different for the 3 levels

6.7.43. Function 59 - Change access level

By entering function 59, the command line will prompt for a password.

Key in the 4 digits password from Function 58 for the desired access level for the operator and
press ENT.

Password protecting the MC12 is realised by establishing 3 Levels of operability from the
keyboard. The idea is to limit the number of functions and key's available to the operator. In
praxis the operator will have no response from the MC12, when trying to use functionality that
have been excluded in the current level.

When the MC12 is in Level 2 or 3 and parameters are to be changed or another programme to
be loaded, the supervisor must use Function 59 and key in the password for Level 1. Then
make the changes and use Function 59 again to put the MC12 back in Level 2 or 3.


6.7.44. Function 60 - Ext. Input Mode

Mode 1 or 2.
This function is activated when using foot switch in order to start/stop filling.
1- Foot-switch used only as start (Standard setting on FMB)
2- First push starts Second push stops Third push starts etc.

6.7.45. Function 70 – Cap. format

Capacity format: The number of fills carried out by the system can be measured per hour or per
minute.

1 = Fills per minute
2 = Fills per hour

Enter the required output format followed by and it will be displayed in Function 10.

Function 70 is not shown in the status lines of the display.

6.7.46. Function 71 - Flow format

The function reads out the current flow rate in the system when the rotor is running with the
programmed number of revolutions per minute.

This flow format can be read out in the following units:

1 = millilitres per minute

2 = millilitres per hour

3 = litres per minute

4 = litres per hour

5 = kilos per minute

6 = kilos per hour

The system will only accept a number from 1 to 6 as described above.