625l pumphead, 625l installation – Watson-Marlow 624Di User Manual
Page 19

Watson-Marlow Bredel E-Manuals
http://www.watson-marlow.it/pdfs-global/m-624Di-gb-01.htm[10/07/2012 13:59:15]
3
MR2000C
Track
4
MRA0249A
Roller assembly element pumphead
<4>
MRA0250A
Roller assembly continuous pumphead
5
MR2027T
Controlled waste threaded fitting 620R
6
MR2028M
Controlled waste port blanking plug
7
MR2018T
Hinge pin
8
MR2055M
Rotor cover
9
MR2021B
Seal - guard
10
MR2002M
Guard without latch and seal
11
MR2015T
Follower roller spindle
12
CX0148
Roller assembly circlip (snap-ring) E type 6 dia
12
MR2014T
Stainless steel roller spindle
12
MR2010T
Thrust washer
13
MR2096T
Controlled waste threaded fitting locking nut
14
MRA0320A
Rotor assembly 2-roller element
14
MRA0321A
Rotor assembly 4-roller element
14
MRA0322A
Rotor assembly 2-roller continuous
15
MR2058B
Grommet - door switch
16
XX0220
Key - metal
17
MR2029T
Cased drive MG605 shaft/rotor hub spacer
18
MR2059T
Adaptor - Bodine (white polypropylene ring)
19
FN0488
Cased drive track locating screw M6x10 locating bolt
20
FN0523
Close-coupled track locating screw M6x20 locating bolt
21
FN0581
Rotor locating washer M6
22
FN0520
Rotor locating bolt M6 x 25
23
TT0006
5mm Allen key
24
MA0017
Guard magnet
CN0187
Plug blanking 10.72M
MRA0268A
Cased drive door switch assembly
MRA0279A
Close-coupled door switch assembly
625L Pumphead
The twin offset track design of the 625L utilises 4.0mm wall double-Y tube elements to
overcome pulsation for accurate dosing and dispensing. The 625L accepts Silicone and
Marprene tubing up to 16.0mm bore. Use 4.0mm wall tube for transfer for the highest
performance and improved viscous fluid handling.
Alternatively the 625L will run with two separate tubes although some channel to channel
variance and minimal pulsation may be experienced. For separate tube fitting or twin tube
inlet to single tube outlet fitting tube clamping blocks must be used.
625L Installation
Remove the mounting plate cover and track from the 625L. Locate 625L to pump. Tighten
top and bottom mounting plate screws. To remove the pumphead lift off the mounting
plate cover and track, loosen the top and bottom mounting plate securing screws and ease
pumphead away from the pump.