Locate the corresponding guard clamp halves which have raised "T" locating

sections, into the slots on the inner guard face above and below the guard hinge.

Push and slide into their locked position.

Closing the guard will align the two halves of the clamp around the tubing.

620RE and 620RE4 tube element loading

620RE element pumpheads are factory set to accept Watson-Marlow LoadSure tube

elements. Pumping performance will be adversely affected if LoadSure elements are

not used.

Disengage rollers

Locate one of the "D"-shaped flanges into the lower port. (The "D" flange ensures

that the element can only be loaded correctly).

Wrap the tube element around the disengaged rollers of the rotor.

Locate the second "D"-shaped flange into the upper port.

Ensure the flat face of each "D" flange sits flush to the flange sealing face of the

track.

Engage rollers

Close the guard and push it against the track until the latch engages.

Tube element loading

620RE, 620RE4 and 620R Continuous tube loading

620R continuous tubing pumpheads are factory set to accept Watson-Marlow 600

series 3.2mm wall tubing. Pumping performance will be adversely affected if

Watson-Marlow tubing is not used.

Select the tube clamp set which is correct for the tubing size to be used.

Disengage rollers

Locate one end of the tubing into the lower port "U" clamp and hold firmly in

position.

Wrap the tubing tightly around the retracted rollers, making sure that there is no

twisting through its length.

Locate the other end of the tubing into the upper port "U" clamp.

Hold both ends of the tubing in one hand maintaining tension around the retracted

rollers.

Engage rollers

Close the guard and push it against the track until the latch engages

Ensure that continuous tubing is not loosely clamped at the pumphead ports.

Ensure that when the pump is re-started all of the rollers have re-engaged. A roller

which has not re-engaged will "click" continuously. No damage will occur if this

happens but the roller should be re-engaged manually using the 5mm Allen key.

Please refer to the Troubleshooting section.

Continuous tube loading