beautypg.com

Verilink TAC 2130 S/T (880-503296-001) Product Manual User Manual

Page 33

background image

Configuration

Verilink TAC 2130 User Manual

3-11

49

NCC 2020

NCC 2130

SCC 2020

SCC 2130

TAC 2010

TAC 2130

Network LBO = 15 dB; Attenuates transmit signal by 15db. USE ONLY

IF NO SMART JACK IS PRESENT. Implies that the first active device

(repeater, T3 mux, far CSU) is 0 to 1000 feet away.

50

NCC 2020

SCC 2020

TAC 2010

Selects DSX-1 Equipment cable length of 0-132 ft.

51

NCC 2020

SCC 2020

TAC 2010

Selects DSX-1 Equipment cable length of 133-265 ft.

52

NCC 2020

SCC 2020

TAC 2010

Selects DSX-1 Equipment cable length of 266-398 ft.

53

NCC 2020

SCC 2020

TAC 2010

Selects DSX-1 Equipment cable length of 399-532 ft.

54

NCC 2020

SCC 2020

TAC 2010

Selects DSX-1 Equipment cable length of 533-655 ft.

55

NCC 2020

SCC 2020

TAC 2010

DIU 2140

Sets data bus to NONE (CSU mode) [default].

56

NCC 2020

SCC 2020

TAC 2010

DIU 2140

Sets data bus to A (Mux mode).

57

NCC 2020

SCC 2020

TAC 2010

DIU 2140

Sets data bus to B (Mux mode).

58

NCC 2020

SCC 2020

TAC 2010

DIU 2140

Sets data bus to C (Mux mode).

59

NCC 2020

NCC 2130

SCC 2020

SCC 2130

TAC 2010

TAC 2130

Sends in-band CSU loop-up code to far-end CSU, this should cause the

far end CSU to enter a Line Loopback condition.

Code

Applies to

Description