Configuration

This chapter covers configuring the CSU/DSU portion of the TAC
2130, TAC 2130-S, and TAC 2130-T IDCSU modules. Use of the Craft
interface and the front panel thumbwheel switches is documented
in this chapter.

Using the Craft Interface

To access the Craft interface, connect a terminal or a computer
running a terminal program to the port labeled

CRAFT

or

LOCAL

on the

front panel of the node controller module.

Craft Port

Terminal Setup

Set your terminal parameters to:

Data Rate : 19.2 kbit/s

Word Size : 8 bits

Parity : None

Stop Bits : One

Flow Control: None

The Verilink Craft interface does not assert any control leads.

Verilink provides two different types of Craft cable. Both versions
of the Craft cable have an RJ-11 modular connector at one end. The
original cable has a female DB-25 connector at the other end and a
more recent version has a DB-9 female connector. Connect the RJ-
11 modular connector to the port labeled

CRAFT

or

LOCAL

on the front

of the node controller module.

The original Craft cable pinout is as follows:

Table 3-1 Verilink Craft Cable P/N 458-501788-008

An alternative Craft cable uses DB-9 and RJ-11 connectors. It is
wired according to the pinout shown in

Table 3-2

.

DB-25 female

RJ-11 modular

Usage

pin 2

pin 3

Transmit Data

pin 3

pin 4

Receive Data

pin 7

pin 5

Signal Ground