Quick Set-Up
2-4
Verilink TAC 2130 User Manual
2. By default, all 24 timeslots of the T1 are assigned to the data
port. For this example, only the first twelve are used. Type “D”
and press E
NTER
. The prompt used to select timeslots appears,
ENTER CHANNELS
ENTER CHANNELS
ENTER CHANNELS
ENTER CHANNELS. Type “1-12” and press E
NTER
.
3. The default value for the density enforcement selection is not
correct for a B8ZS T1. Use the
ZZZZ command, select “1” and press
E
NTER
to change it to NONE. B8ZS was developed to eliminate
the need for density enforcement.
NOTE: For the remainder of this chapter you will not be instructed
to press E
NTER
each time. Generally, the E
NTER
key is used
after each command or value entry.
4. Cisco™ routers wrap the transmit clock signal provided by the
DSU back toward the DSU on the optional third clock pair,
Terminal Timing. Whenever the DTE offers this feature, it
should be used, since the clock on the TT pair will be perfectly
in phase with the Transmit Data provided by the DTE. Use the
C
C
C
C command and choose “3” for Terminal Timing.
5. There are no more changes required to the default IDCSU
configuration for this example. Use the
XXXX command to return
to the TAC 2130-T Main Menu.
The T1 circuit and DTE should now be connected.
When the router cable is connected to the IDCSU, the EQPT LED
stops blinking and is lit steady green.
Within 15 seconds of connecting the T1 circuit, the NET LED on the
TAC 2130-T should change from red to green. If it does not, the
Diagnostics Menu can be used for troubleshooting. See
for more information on diagnostics.
When the IDCSU has been connected to the T1 circuit for at least
fifteen minutes, performance statistics will be available under the
Performance Menu. See
for more details.
The configuration of the TAC 2130-T is covered in detail in
of this manual.
Resetting the
STAT LED
The STAT LED normally remains red for up to fifteen minutes after
all alarm conditions are cleared. To force the STAT LED to assume
its typical condition (off) follow these steps:
1. From the Main Menu, use the
PPPP command to select the
Performance Menu.
2. Use the
RRRR command to reset the registers (all information
stored in the ESF registers for the preceeding 24 hours is
cleared).
3. Use the
XXXX command to return to the Main Menu.