beautypg.com

Utilities -20, Utilities – Verilink PRISM 3021 (34-00262) Product Manual User Manual

Page 42

background image

4-20 Terminal Operation

PRISM 3021

Utilities

The Utilities screen (Figure 4-18) handles the functions
described in the following paragraphs.

S

ET

T

IME

The current time may be entered in this field using the 24 -

hour HH :MM:SS format. For example, 3:45 a.m. is entered

as 0345 and 3:45 p.m. is entered as 1545.

S

ET

D

ATE

The current date in the may be entered in this field using the
MM:DD: YY format. For example, July 4, 1993 is entered
as 070493.

D

ATE

F

ORMAT

This fields allows selecting an International or Standard date
format. International dates are displayed with the year,
month, then day. Standard dates are displayed with the
month, day, then year. This setting activates after exiting
and re-entering the terminal session.

N

EW

P

ASSWORD

This field allows entry of a password of up to 10 characters.
An empty string (ENTER key only) may be entered to dis-
able the password feature. After ENTER is pressed, the new
password is activated and is no longer visible. Therefore,
type carefully when entering a new password and verify
before pressing ENTER. When the terminal interface is
exited and later reactivated, this password must be entered
exactly to gain access. If the wrong password is entered, the
following message appears:

Incorrect Password; Please Enter Again.

Do not exit the terminal interface pro-
gram until the password procedure is

fully understood. If a password has been
specified, it must be typed exactly to reenter
the program.

If a password is programmed and later forgotten, contact
TxPORT Technical Support for a one-time backdoor pass-
word. Prior written approval must be sent to TxPORT
before the password can be issued.

The reset operation sets all parameters to the
factory default settings and zeros all perfor-
mance registers.

Figure 4 -18 Utilities Screen

3021 DSU 1.00/1.01 P R I S M 3 0 2 1 Date: 1997-03-21

No Far End Response Time: 13:54:16

----------------------------------- UTILITIES --------------------------------

Set Time: (13:54:13) (hh:mm:ss)

Set Date: (03/15/96) (mm/dd/yy)

Date Format: [International]

New Password: ( )

(MAINTENANCE RESET)

(FACTORY RESET)

----------------------------------- Messages ---------------------------------