Terminal Operation 4-19

PRISM 3021

Initialization String: The modem initialization string is
entered in this field. Refer to the modem’s documentation
for further information. The default setting is

ATEQ0V1

.

Disconnect String: This field identifies the character string
to be output when the modem session is terminated. The
default setting is

ATH

.

S

UMMARY

The Summary screen (Figure 4-17) is a display-only screen
that summarizes all the configuration switch settings in the
left column. For definitions of the switch settings, refer to
Unit Configuration on page 2-1. Other pertinent informa-
tion is shown in the right column.

Figure 4-17 Summary Screen

3021 DSU 1.00/1.01 P R I S M 3 0 2 1 Date: 03/15/96

No Far End Response Time: 13:54:00

------------------------------------ SUMMARY ---------------------------------

(S1:1) Net Framing: CAS Serial Num: 001199

(S1:2) Net CRC4 Enabled

(S1:3) Net Coding: HDB3

(S1:4-5) Timing Source: Network

(S1:6) Keep Alive: Unframed

(S1:7) Data : Normal

(S1:8) Prgm Flash: Disabled

(S2:1-8) HDW Address: #x0

(S3:1-2) NMS Port Rate: 19200 ------ Unit Options -------

(S3:3-4) Supv Port Rate: 38400 Port 1: V.35

(S3:5-6) Boot Mode: Switches Port 1 Rate: 0 kHz

(S3:7) Port Mult: Nx64

(S3:8) Assignment: Altern Option Card: E1-DTE

(S4:1-5) N-Select: 0 (S4:1) DTE CRC4: Enabled

(Rot SW1) National Bits: None (S4:2) DTE LineCode: HDB3

(3-pos) TestLoop: No -Loop (S4:3-7) DTE Spare:

(S4:8) DTE Ohms: 75