2-2 Installation

PRISM 3021

Configuration Switch S1

Switch S1 (Figure 2 -2) is used to set the configuration
parameters listed in the following paragraphs.

Factory default settings are underlined through-
out this manual.

N

ETWORK

F

RAMING

Position S1-1 is used to select Channel Associated Signaling
(CAS) network framing or Common Channel Signaling
(CCS) network framing as shown in Table 2-A.

CRC4 M

ODE

Position S1-2 is used to enable or disable CRC4 as shown in
Table 2-B.

N

ETWORK

L

INE

C

ODE

Position S1-3 selects High-Density Bipolar of order 3
(HDB3) line code or Alternate Mark Inversion (AMI) line
code as shown in Table 2-C. HDB3 provides clear channel
capability.

T

IMING

S

OURCE

Positions S1-4 and S1-5 are used to select the source of unit
clocking as shown in Table 2-D. Deriving timing from the
network is the most common timing source for most applica-
tions. The unit may also be clocked from its internal oscilla-
tor; from equipment attached to the DTE; or from equipment
attached to the E1-DTE option card.

K

EEP

A

LIVE

F

RAMED

AND

U

NFRAMED

O

NES

Position S1-6 selects keep alive framed and unframed ones
as shown in Table 2-E. Keep alive is generated when the
unit detects LOS or OOF.

Table 2 -A Network Framing

Functions

S1-1

Network Framing CAS

Down

Network Framing CCS

Up

Table 2-B CRC4 Mode

Functions

S1-2

CRC4 enabled

Down

CRC4 disabled

Up

Switch S1

8

1 2 3 4 5 6 7

Switch S2

8

1 2 3 4 5 6 7

Switch S3

8

1 2 3 4 5 6 7

Switch S4

5

1 2 3 4

Figure 2-1 Top-Edge View of the PRISM 3021

7

6

5

4

3

2

1

Do

wn

Up

8

Network

CRC4

Network

Data

No

rmal

Pro

g

ram

Fra

m

ing

Mo

de

Fla

sh

o

r In

v

erted

K

e

ep Al

iv

e F

rame

d

an

d

Un

fr

a

m

ed

On

es

Lin

e Cod

e

Ti

m

in

g

So

urc

e

Ti

m

in

g

So

urc

e

Figure 2-2 Switch S1

Table 2 -C Network Line Code

Network Line Code

S1-3

HDB3

Down

AMI

Up

Table 2 -D Timing Source

Timing Source

S1-4

S1-5

Network

Down

Down

Internal

Down

Up

E1 DTE

Up

Down

DTE or External

Up

Up

Table 2-E Keep Alive Framed and Unframed Ones

Mode

S1-6

Keep Alive Unframed Ones

Down

Keep Alive Framed Ones