DIU/DIM Details
7-4
Verilink
Figure 7-6 Send Timing (ST)
Since TT must be locked to ST, most DTE manufacturers turn ST
around on TT, and TT is usually an exact duplicate of ST. (Figure
7-7)
Figure 7-7 Interface Timing Options
Therefore, the DIU can be set to clock in SD using ST instead of TT.
Consequently, some DTE manufacturers do not implement the TT
signal. If the cable between the DIU and DTE is long enough, the
DIU may require setting the clock for inverted ST rather than ST;
this allows for a slight phase shift.
For the DCE-DTE interface to function properly, the data signals
must be synchronized with the associated clock signals. Therefore,
the following signals (if implemented) must be synchronized:
•
RD with RT
•
TT with ST with SD
In the T1 transmit direction, SD and TT (if implemented) must both
be synchronized with ST. The ST is derived from the T1 transmit
clock, and is generated using one of one the following timing
methods (Figure 7-8):
•
Network Loop Timing (T1 Bit Stream)
•
Internal Timing (Master Clock)
•
External Timing (Station Clock)
Customer
Equipment
(DTE)
DSU
(DCE)
T1 XMT
T1 RCV
Clock
Recovery
Receive
Input Buffer
SD
RD
TT
RT
Buffer
ST
XMT Buffer
Customer
Equipment
(DTE)
DSU
(DCE)
T1 XMT
T1 RCV
Clock
Recovery
Receive
Input Buffer
SD
RD
TT
RT
Buffer
ST
XMT Buffer
TT
ST
ST