Diu 2130 configuration, Configuration options and default settings, Diu 2130 configuration -1 – Verilink DIU 2130 (880-503297-001) Product Manual User Manual
Page 25: Configuration options and default settings -1, Chapter

Verilink
3-1
Chapter
3
DIU 2130 Configuration
Before configuring a DIU 2130, verify that:
•
A data bus has been assigned to the CSU of the associated
NCC, SCC, or TAC. This bus conveys customer data between
the DIUs and the CSU during normal operation.
•
The proper DIU timing mode has also been selected on the
associated CSU.
Configuration
Options and
Default Settings
Table 1-1 provides the DIU 2130 configuration options and factory
default settings. These settings allow the DIU to interface properly
with the customer equipment and the associated CSU for T1
network transmission. The DIU 2130 is shipped with the default
settings listed in the table.
Table 3-1
DIU 2130 Configuration Options and Default Setting
Description
Options
Default
Setting
Data port speed
56 kbit/s to 1.536 Mbit/s in multiples of 56 or 64
kbit/s
--
Data mode = 64 kbit/s
Yes or No
No (56
kbit/s)
CA, RTS, or RS control lead
Yes = forced on,
No = follow DTE input
No
CD, DTR, or TR control lead
Yes = forced on,
No = follow DTE input
No
CB, CTS, or CS control lead
Yes = always on,
No = follow CA, RTS, or RS; turned off during alarm
No
CC, DSR, or DM control lead
Yes = always on,
No = follow CD, DTR, or TR; turned off during alarm
No
CF, RR, or RLSD control lead
Yes = always on,
No = follow CD, DTR, or TR; turned off during alarm
No
Data channel loopback enable
Yes or No
No
Timing Unit enable
Yes or No
No
Data equipment clock
TT, ST, or inverted ST (ST)
TT or ST