T1 Dial Backup Option Overview

5-10

Verilink

Figure 7

Status Display Screen for DIU213 0/DBU

Under Port 1, one of the following codes can result:

ACTIVE

No errors are detected and the port is operating normally.

ASC

The port switched due to an Abnormal Station Code on Port
1.

LOF

The port switched due to Loss Of Frame.

CD

The port switched due to Carrier Detect received from the
backup circuit DCE.

USER

The port switched due to user command.

Under Port 2 one of the following codes may result:

STANDBY

The backup circuit is currently not being used.

ACTIVE

Errors detected on Port 1 (or by user command) caused the
backup circuit to become active.

ERROR

The backup criteria was met but an attempt to establish the
backup circuit failed.

Managing Alarms and Testing

Managing Dial

Backup Alarms

Table 2 lists the possible alarms that can occur during the
DIU 2130/DBU operation.

/