Verilink DIU 2130 (880-503297-001) Product Manual User Manual
Page 32

DIU 2130 Configuration
3-8
Verilink
Timeslots
All timeslots from 1 to 24 are listed across the screen on the eighth line of the
display. Below this line, beneath each timeslot, the dataport to which that
timeslot is assigned is indicated. Thus, for each of the timeslots 1 through 24,
either a 1, a 2, or a pair of dots indicating unassigned will be shown. For
example:
chnl 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
24
Dp)port 01 01 01 01 .. .. .. .. 02 02 02 02 .. .. .. .. .. .. .. .. .. .. .. ..
In this example, timeslots 1 through 4 are assigned to the first DIU 2130
dataport and timeslots 9 through 12 are assigned to dataport 2.
To assign timeslots to the dataports, use the command
D
p; however, do not
use the lowercase p. Instead, use either a
1
or a
2
in place of the lowercase p.
The lowercase p is used as a variable.
Multiple timeslots are entered by separating the numeric values with a comma
or a minus sign. In the example below, the first twelve timeslots are assigned to
dataport 1:
[1,2] DIU 2130 > d1
enter port 1 channels > 1-12
[1,2] DIU 2130 (UPDATE) >
DTR
Data Terminal Ready—a control lead presented by the DTE (Data Terminal
Equipment). The Verilink DIU 2130 is DCE (Data Communications Equipment)
which expects to receive DTR as an input from the DTE indicating it is present,
powered up and prepared to operate.
If the DTE does not assert DTR, this option allows the DIU 2130 to behave as it
would if DTR were asserted by the DTE.
This feature can be set independently for port 1 and/or port 2.
The user types "DTR" and gets this response:
force dtr handshake port(s) (1) 1 (2) 2 (3) both (4) none >
The display as shown in our example reflects DTR forced on port 1 and not on
port 2.
DSR
Data Set Ready—a control lead presented by the DCE (Data Communications
Equipment). The Verilink DIU 2130 is DCE. The DIU expects to receive DTR as
an input from the DTE indicating it is present, powered up and prepared to
operate.
This option allows the DIU 2130 to assert DSR regardless of any DTE leads.
This feature can be set independently for port 1 and/or port 2.
The user types "DSR" and gets this response:
force dsr handshake port(s) (1) 1 (2) 2 (3) both (4) none >
The display shown reflects DSR forced on port 1 and not on port 2.
Command
Options