beautypg.com

Verilink ConnecT 56K DSU (896-502110-001) Product Manual User Manual

Page 70

background image

Operation

3-40

ConnecT 56K DSU User Manual

Submenu A SR options

The SR Options menu is used to select the operating mode for the data set
ready (SR) lead.

Menu map

3=CONFIG/1=Local/2=DTE Opt./A=SR Options

Operation

To display the SR Options submenu of 1=Local submenu of 3=CONFIG.
Use the scroll buttons to display the 9=Tr Options and A=SR Options.
Press the * (Shift) key to activate the alpha selections Use the letter A to
activate the SR Options submenu press the Enter key to enter the SR
Options submenu resulting in the displaying of the first of the SR Options
submenu items.

1=Forced On

2=Off OOS ONLY

Continue with standard operating procedures to select menu options. At
the end of the options the system will briefly display “Command
Accepted” and return to the active menu.

Table 3-27 SR Options Commands

Submenu B seconda y rate

The Secondary Rate option is used to select the operating speed for the
secondary channel if the secondary channel option was selected during
setup of the NETWORK OPT.

Front Panel

AT
Command

Description

1=FORCED ON

&S0

SR always ON

2=OFF OOS ONLY

&S1

OFF when network out of service

3=OFF LOCD ONLY

&S2

OFF 5 seconds after disconnect
in switched 56 applications.

4=OFF TEST ONLY

&S3

OFF for test only

5=OFF TEST + OOS

&S4

OFF for test or OOS

6=OFF TEST + LOCD

&S5

OFF 5 seconds are disconnect for
test