Verilink ConnecT 56K DSU (896-502110-001) Product Manual User Manual
Page 57

3 = CONFIG
ConnecT 56K DS
User Manual
3-27
Submenu 1 loop rate
The LOOP RATE option sets the loop operating speed. The unit should
be set to the rate required by the DDS Service. The ConnecT 56K DSU
also supports subrate DTE data over a 56K loop. The loop rate must be
set independently of the DTE rate.
Eight loop rate elections are available. After selecting any loop rate other
than Auto or 64K (1 or 8), the option for a secondary channel is available.
The various loop rates and format selections are listed below with the
equivalent AT commands that perform the same configuration functions.
Table 3-12 Loop Rate Commands
Front Panel
AT Command
Selections Description
1=AUTO
%B0
DSU auto rate adapts to
network
2=2.4K NO SEC. CH
%B1
2.4K with no secondary
channel
3=4.8K NO SEC. CH
%B2
4.8K with no secondary
channel
4=9.6K NO SEC. CH
%B3
9.6K with no secondary
channel
5=19.2K NO SEC. CH
%B4
19.2K with no secondary
channel
6=38.4K NO SEC. CH
%B5
38.4K with no secondary
channel
7=56K NO SEC. CH
%B6
56K with no secondary
channel
8=64K NO SEC. CH
%B7
64K with no secondary
channel
2=2.4K SEC. CH
%B9
2.4K with secondary channel
3=4.8K SEC. CH
%B10
4.8K with secondary channel
4=9.6K SEC. CH
%B11
9.6K with secondary channel
5=19.2K SEC. CH
%B12
19.2K with secondary
channel
6=38.4K SEC. CH
%B13
38.4K with secondary
channel
7=56K SEC. CH
%B14
56K with secondary channel