Verilink ConnecT 56K DSU (896-502110-001) Product Manual User Manual
Page 48

Operation
3-18
ConnecT 56K DSU User Manual
Figure 3-8 DTE WITH TP MENU
Menu map
2=TEST/1= LOCAL UNIT/4=DTE WITH TP/Submenus 1-6/Displays
Operation
Follow standard operating procedures. When 4=DTE With TP is flashing:
Press the Enter button resulting in the system briefly displaying “Please
Wait” after which it displays the first of the test results.
1=2047 PATTERN
2=511 PATTERN
Continue with operational procedures described for DTE & Loop (LL).
Table 3-7
DTE With Test Pattern Commands
1=2047 Pattern
Selects the 2047 Pattern
2=511 Pattern
Selects the 511 Pattern
3=Stress Pattern #1
Selects DDS Stress Pattern 1
4=Stress Pattern #2
Selects DDS Stress Pattern 2
5=Stress Pattern #3
Selects DDS Stress Pattern 3
6=Stress Pattern #4
Selects DDS Stress Pattern 4
Front Panel
AT Command
Description
1=EXIT TEST
_T0
Standard 2047 random data pattern
2=DISPLAY STATUS
_T1
Standard 511 random data pattern
3=STRESS PTRN #1
_T2
DDS stress pattern #1
4=STRESS PTRN #2
_T3
DDS stress pattern #2
5=STRESS PTRN #3
_T4
DDS stress pattern #3
6=STRESS PTRN #4
_T5
DDS stress pattern #4
1=2047 PATTERN
2=511 PATTERN
3=STRESS PTRN #1
4=STRESS PTRN #2
5=STRESS PTRN #3
6=STRESS PTRN #4
4=DTE WITH TP
LOOP 56K
DTE 56K SYNC
TR
OFF
SR LLB RLB
OFF OFF
OFF
UNIT IN TEST
LOOP IS NORMAL
DTE WITH TP
TST ERR=00
Displays