Verilink ConnecT 56K DSU (896-502110-001) Product Manual User Manual
Page 61
3 = CONFIG
ConnecT 56K DS
User Manual
3-31
Submenu 1 DTE rate
The DTE RATE option sets the operating speed of the DTE interface
when the unit is set for 56K. The ConnecT 56K DSU supports six
different DTE rates over a 56K Loop.
Use the number of the desired DTE RATE to activate the selectio n press
Enter to select the DTE Rate resulting in the system briefly displaying
“Command Accepted” and returning to the DTE OPTIONS menu with
the DTE RATE selection active.
If a loop rate of 56k or 64K was chosen during NETWORK OPT.
configuration, then the following DTE RATE menu is shown:
Table 3-17 DTE Rate Commands
If a loop rate of 56k with secondary channel or 64K was chosen during
NETWORK OPT. configuration, then the following DTE RATE menu is
shown:
Table 3-18 Loop Rate of 56K
Note:
For point-to-point operation at 56K with secondary channel, the
network requires that both the primary and secondary channel
data not be zero simultaneously. For those applications where
HDLC protocol is being used, the above constraint can be
eliminated by selecting the DATA INVERT OPTION. The
Front Panel
AT Command
Description
1=DTE 56K/57.6K
%K8
DTE rate: 56K sync or 57.6K
async
2=DTE 2.4K
%K3
DTE rate 2.4K sync and async
3=DTE 4.8K
%K4
DTE rate 4.8K sync and async
4=DTE 9.6K
%K5
DTE rate 9.6K sync and async
5=DTE 19.2K
%K6
DTE rate 19.2K sync and async
6=DTE 38.4K
%K7
DTE rate 38.4K sync and async
Front Panel
AT
Command
Description
1=SCRAMBLER OFF
_F0
DTE data scrambler disabled
2=SCRAMBLER ON
_F1
DTE data scrambler enabled
3=DATA INVERT
_F2
DTE data invert enabled