![background image](https://www.manualsdir.com/files/808509/content/doc052.png)
Operation
3-22
ConnecT 56K DSU User Manual
Status Displays
Remote With TP
TEST Err - 00
Table 3-8
Test Displays
Table 3-9
Available interface leads
1 = Exit Test and 2 = Display Status
The menu choices here are used to immediately exit the test selection or
to re-enter status display. These menu items are available only after tests
have been performed.
When a test has been requested, the system briefly displays “Please Wait”
before presenting the first test display. At any test result display: Press the
Quick # key to access the 1=EXIT TEST/2=DISPLAY STATUS submenu
or press the Cancel key to change from the status display to the main
menu resulting in the TEST selection being active (flashing).
Local DTE & Loop
Type of test being performed
Loop 56K
Loop rate
DTE 56K Sync
DTE rate and data type
TR
Terminal Ready Input
SR
Set Ready Output
LLB
Local Loopback Input
RLB
Remote
Loopback
Input
OFF/ON
State of the respective leads displayed immediately
above.
Unit in Test
Operating mode to ConnecT 56K DSU
Loop is Normal
Status of network service
1=EXIT TEST
Will effectively exit the testing process
returning to the Main Menu for selection.
2=DISPLAY STATUS
Re-enters test display for additional
viewing.