AC Current

Range

Resolution

Accuracy

2.000mA 1µA ± (1.2% rdg + 3 digits)

200.0mA 100µA ± (2.0% rdg + 3 digits)

20.00A 10mA ± (3% rdg + 10 digits)

Overload Protection: 0.2A / 250V fuse

(below 200mA range)

20A /250V fuse (20A range)

Limit measurement time on 20A range to 30 seconds

for inputs over 10A. Allow 15 minutes cool down

between measurements.

Display: Average Value (RMS of Sine Wave)

Resistance

± (1.0% rdg + 4 digits)

after subtracting any

residual resistance noted

when test leads are shorted.

± (1.0% rdg + 2 digits)

± (1.2% rdg + 2 digits)

± (2.0% rdg + 5 digits)

± [5% (rdg-10) + 10 digits]*

200.0Ω

2.000KΩ

20.00KΩ

200.0KΩ

2.000MΩ

20.00MΩ

200.0MΩ

0.1Ω

1Ω

10Ω

100Ω

1KΩ

10KΩ

100K

Range

Resolution

Accuracy