5: SPECIFICATIONS

5.1 Display: ..............................1.4” (35mm) high LCD
5.2 Display Resolution: ............2000 counts, 0000 to 1999
5.3 Overrange Indication: .........First digit displays “1”, remaining

digits are blank

5.4 Measurement Rate: .............2 times per second
5.5 Low Battery Annunciator: ..

5.6 Operating Conditions:
Temperature: ......……........0 to 50 degrees C
(32 to 122 degrees F)
Relative Humidity:…...........less than 70%
5.7 Storage Conditions:
Temperature: .......…...........-20 to 60 degrees C
(-4 to 140 degrees F)
Relative Humidity….............less than 80%
5.8 Case Dimensions: ...............17.8 x 8.2 x 5.6 cm, (L x W x H)

7 x 3.2 x 2.2 inches (L x W x H)

5.9 Weight (w battery) ………..Approx 400 grams, 0.88 lbs.
5.10 Battery: ...................…........1 standard 9 volt alkaline battery

NEDA 1604, Triplett Part No. 37-48

5.11 Battery Life: ........…............Typically 200 hours
5.12 Fuses: .................…............0.2A / 250 volt FAST, 5 x 20mm

fuse, for mA ranges. Triplett

Part No. 3207-133