beautypg.com

Technical characteristics – Tecfluid CU Series User Manual

Page 41

background image

41

12

TECHNICAL CHARACTERISTICS

Accuracy

± 1,5% of reading ± 0,02 m/s

Repeatability

± 0,25% of reading ± 0,01 m/s

Velocity

range

0,2 ...12 m/s

Temperature

Process temperature: -20 ºC … 80 ºC
Ambient temperature range:

-20 ... +60 ºC

Power

supply

85 ... 265 VAC 50, 60 Hz .
Power consumption: ≤ 5 VA

Analog

output

4-20 mA. Active or passive. galvanically isolated from the power supply.

Relay

outputs

Two changeover contacts, SPDT, potential free

Contact

characteristics:

Maximum voltage

: 250 VAC

Maximum current

: 8 A

Maximum power

: 500 VA

Totalizer

N. of digits:

8 (2 decimals)**

Digit size:

8 mm

Reset:

by means of keyboard

Flow rate and velocity indication
Nº of digits:

5 (up to 2 decimals configurable)**

Digit size:

11 mm

** When the available digits are full and the integers overflow a decimal is automatically

lost.

General

characteristics

Materials:

Transducers

: Anodized aluminium and PEEK

Housing :

ABS

Ingress protection (transducers and housing): IP65

Maximum transducer cable length: 50 m


Conforms to Low voltage Directive 2006/95/EC
Conforms to Electromagnetic compatibility Directive 2004/108/EC

12