SSi Manual Series 9010 – eSPP Programmer
Page 50
Atmosphere Instruments
Controller
Source
Location
Write
Register
Read
Scale
Write Scale
Description
AC20
11
123
1
1
%C Actual
(Modbus Mode)
29
138
1
1
%C Setpoint
13
125
1
1
Probe Temperature
10
122
1
1
Probe Millivolts
20
130
10
10
%C Percent Output
34
142
1
1
CO Factor or Equivalent
35
143
1
1
H Factor or Equivalent
12
124
1
1
Dew Point
36
144
10
10
O2
Controller
Source
Location
Write
Register
Read
Scale
Write Scale
Description
Yokogawa 750
2
2
1
1
%C Actual
(Modbus Mode)
3
100
1
1
%C Setpoint
20
19
1
1
Probe Temperature
10
122
1
1
Probe Millivolts
4
4
10
10
%C Percent Output
0
0
1
1
CO Factor or Equivalent
0
0
1
1
H Factor or Equivalent
Controller
Source
Location
Write
Register
Read
Scale
Write Scale
Description
UDC 3300’s
1
0
1
1
%C Actual
(Modbus Mode)
3
2
1
1
%C Setpoint
6
5
10
10
Probe Temperature
5
4
10
10
Probe Millivolts
4
3
10
10
%C Percent Output
43
39
10
10
CO Factor or Equivalent
43
39
10
10
H Factor or Equivalent
Controller
Source
Location
Write
Register
Read
Scale
Write Scale
Description
Dualpro Loop 1
21
20
1
1
%C Actual
(Modbus Mode)
7
6
1
1
%C Setpoint
18
17
8
8
Probe Temperature
19
18
8
8
Probe Millivolts
41
40
41
41
%C Percent Output
4
3
1
1
CO Factor or Equivalent
5
4
1
1
H Factor or Equivalent