TITLE: MODBUS/J-BUS Protocol for SSi’s- AC20 ENG. 824E REV. 1

WORDS FOR DEVICE IN CONFIGURATION MODE - PARAMETERS

“Inpt.” - Menu Conf. 1 - MAIN/AUXILIARY INPUT CONFIGURATION

ADDRESS

(decimal)

DEC.

Display

R

W

R

JBus

Mod

Bus

DESCRIPTION

FIGU-

RES

MNEM

CODE

E
A
D

I

T
E

2001

2000

Line frequency

Range:

0 = 50 Hz

1 = 60 Hz

N.A.

(“Ln.Fr”)

x

x

2002

2001

Primary variable selection

Range:

0 = Carbon potential as primary control
variable (the span limits are 0.00
to 2.00)
1 = Dew point as primary control variable
(the span limits are -100 to 100°F or
-75 to 40°C)
2 = Sensor output in mV as primary
control variable (the span limits are 0
to 1500 mV)

N.A.

(“PV.SL”)

x

x

2003

2002

Time constant for filter on probe sensor
input (in seconds)

0

(“Pb.FL”)

x

x

2004

2003

Input type and range value for
temperature input

Range:

1 = TC K From -100 to 1370 °C
2 = TC S From - 50 to 1760 °C
3 = TC R From - 50 to 1760 °C
4 = TC K From -150 to 2500 °F
5 = TC S From - 60 to 3200 °F
6 = TC R From - 60 to 3200 °F

N.A.

(“tP.In”)

x

x

2005

2004

Temperature input offset adjustment
(Value in Celsius or Fahrenheit as confi-
gured at Mbus word 2003)

0

(“OFSt”)

x

x

2006

2005

Time constant for filter on temperature
value (in seconds)

0

(“tP.FL”)

x

x

2007

2006

Auxiliary input function for carbon mono-
xide measurement

Range:

0 = Input not used
1 = Input used for CO measurement

N.A.

(“CO.In”)

x

x

2008

2007

Auxiliary input type

Range:

0 = 0

÷

20 mA

1 = 4

÷

20 mA

2 = 0

÷

5 V

3 = 1

÷

5 V

4 = 0

÷

10 V

5 = 2

÷

10 V

N.A.

(“CO.tP”)

x

x