Super Systems AC20 RS485 Modbus User Manual
Page 26
Page 26/59
TITLE: MODBUS/J-BUS Protocol for SSi’s- AC20 ENG. 824E REV. 1
WORDS FOR DEVICE IN CONTROL MODE - NON PARAMETERS
ADDRESS
(decimal)
DEC.
Display
R
W
R
JBus
Mod
Bus
DESCRIPTION
FIGU-
RES
MNEM
CODE
E
A
D
I
T
E
114
113
Status led alarm 1
Range:
0 = Off
1 = On
2 = Flashing (only for alarm)
N.A.
x
115
114
Status led alarm 2
Range:
0 = Off
1 = On
2 = Flashing (only for alarm)
N.A.
x
116
115
Status led alarm 3
Range:
0 = Off
1 = On
2 = Flashing (only for alarm)
N.A.
x
120
119
Variation on alarm status
Note:
Alarm status information is on D8:
(1 for entrance, 0 for exit)
Number of alarm is on low byte (D2-D0)
N.A.
x
121
120
Manufactured trade mark
Value:
50 (32h)
N.A.
x
122
121
Device identification code
Note:
Nr. of software revision x 100 + identifica-
tion code (43)
N.A.
x
123
122
Probe sensor mV value
Note:
When an error is detected on measure,
the “Data field” contains one of these error
codes:
30004 (7534h) = Under-range
30005 (7535h) = Over-range
30050 (7562h) = Error on internal auto-
zero
30051 (7563h) = Error on internal zero-
integrator
0
x
124
123
Carbon potential value
Note:
When an error is detected on measure,
the “Data field” contains one of these error
codes:
30050 (7562h) = Error on internal auto-
zero
30051 (7563h) = Error on internal zero-
integrator
2
x