beautypg.com

Reconfigurable bits, This register is used to set power-down of addac a – Sundance SMT911 User Manual

Page 32

background image

SMT911 User Manual SMT911

Page 32 of 38

Last Edited: 01/06/2010 10:09:00

Same settings as MAXIM A. See corresponding register.


This register is used for general setting and clock mode of ADDAC A.

Byte 1-0

D15 D14

D13

D12

D11

D10

D9

D8

D7

D6

D5

D4

D3

D2

D1

D0

Default

0

0

0

0

0

0

0

0

1

0

0

0

0

0

0

0


Reconfigurable bits:

Bit

Default

Description

15

0

Clock Mode setting. “000” standard FD, HD10, HD20 (modes 1,4,7); “001” Optional FD
timing (mode 2) ; “010” not used; “011” Optional HD20 timing (mode 5); “100” not used;
“101” Optional HD10 timing (mode 8); “110” not used; “111” Clone Mode (mode 10)

14

0

13

0

10

0

Enable the IFACE2 port to be an output clock

9

0

Inv the output clock on IFACE3

7

0

SDIO pin. “0” = uni-directional ; “1” = bidirectional

6

0

SPI Mode. “0” = MSB; “1” = LSB

5

0

Soft Reset. “0” = not reset; “1” = reset register to default value



This register is used to set Power-Down mode of ADDAC A.

Byte 1-0

D15 D14

D13

D12

D11

D10

D9

D8

D7

D6

D5

D4

D3

D2

D1

D0

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0


Reconfigurable bits:

Bit

Default

Description

15

0

Rx_A Analog Power-Down. “0” = active; “1” = Power-down

14

0

Rx_A DC Bias Analog Power-Down. “0” = active; “1” = Power-down

7

0

Power Down Tx Analog. “000” = default; “100 = Power down Tx A;
“010” = Power-Down Tx B; “111 = Power-Down Tx A and Tx B

6

0

5

0

4

0

Tx Digital Power-Down. “0” = active; “1” = Power-down

3

0

Rx Digital Power-Down. “0” = active; “1” = Power-down

2

0

PLL Power-Down. “0” = active; “1” = Power-down

1

0

PLL Output Disconnect. “0” = connect; “1” = disconnect


This register is used to set Power-Down of ADDAC A.

Byte 1-0

D15 D14

D13

D12

D11

D10

D9

D8

D7

D6

D5

D4

D3

D2

D1

D0

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0


Reconfigurable bits:

Bit

Default

Description