Sundance SMT300Q v.1.6 User Manual
Page 46
Page 46 of 61
SMT300Q SMT300Q User Guide V1.65
2
EN2
Same as above for mailbox 2
1
EN1
Same as above for mailbox 1
0
EN0
Same as above for mailbox 0
Table 28 : CompactPCI Mailbox WRITE/READ Interrupt Control Register
14.3.6 Local Bus Mailbox WRITE/READ Interrupt Control Register(Offset Write
0xD4, BAR0 Read 0xD6, BAR0)
Bits Name
Description
15 EN15
CompactPCI
interrupts
on Local bus writes/reads to
mailbox15 enable
14
EN14
Same as above for mailbox 14
13
EN13
Same as above for mailbox 13
12
EN12
Same as above for mailbox 12
11
EN11
Same as above for mailbox 11
10
EN10
Same as above for mailbox 10
9
EN9
Same as above for mailbox 9
8
EN8
Same as above for mailbox 8
7
EN7
Same as above for mailbox 7
6
EN6
Same as above for mailbox 6
5
EN5
Same as above for mailbox 5
4
EN4
Same as above for mailbox 4
3
EN3
Same as above for mailbox 3
2
EN2
Same as above for mailbox 2
1
EN1
Same as above for mailbox 1
0
EN0
Same as above for mailbox 0
Table 29 : Local Bus Mailbox WRITE/READ Interrupt Control Register