Function: Control Room Output Select
Byte
Value Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
01H
Product ID (Model 50)
6
09H
Function: Control Room Output Select
7
nnH
Output Selected, Range 00-33:
L Ch. R Ch. Action
0
0
No Output
1
0
Left Only, Output A On
2
0
Left Only, Output B On
3
0
Left Only, Outputs A & B On
0
1
Right Only, Output A On
0
2
Right Only, Output B On
0
3
Right Only, Outputs A & B On
1
1
Left and Right, Output A On
2
2
Left and Right, Output B On
3
3
Left and Right, Outputs A & B On
8
F7H
EOX, End of System Exclusive
Function: Control Room Mono/Stereo Select
Byte
Value Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
01H
Product ID (Model 50)
6
0AH
Function: Control Room Mono
7
0nH
Output Selected, Range 0-1, 0=stereo, 1=mono
8
F7H
EOX, End of System Exclusive
Function: Control Room Dim
Byte
Value Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
01H
Product ID (Model 50)
6
0BH
Function: Control Room Dim
7
0nH
Status, Range 0-1, 0=No Dim, 1=Dim
8
F7H
EOX, End of System Exclusive