beautypg.com

Studio Technologies 50 2000 User Manual

Page 44

background image

Issue 4, July 2000

Model 50/51 User Guide

Page 44

Studio Technologies, Inc.

Function: Dub Source

Byte

Value Description

1

F0H

System-Exclusive Message

2

00H

1st Byte of Studio Tech ID

3

00H

2nd Byte of Studio Tech ID

4

56H

3rd Byte of Studio Tech ID

5

01H

Product ID (Model 50)

6

06H

Function: Dub Source

7

mnH

Source Selected, m range 0-2: 0=stereo, 1=left only, 2=right only;

n range 0-7: 0=no input, 1=input 1, 2=input 2, etc.

8

F7H

EOX, End of System Exclusive

Function: Control Room Level

Byte

Value Description

1

F0H

System-Exclusive Message

2

00H

1st Byte of Studio Tech ID

3

00H

2nd Byte of Studio Tech ID

4

56H

3rd Byte of Studio Tech ID

5

01H

Product ID (Model 50)

6

07H

Function: Control Room Level

7

0nH

Level, MSB, range 0-3, see note 1

8

nnH

Level, LSB, range 00-7F, see note 1

9

F7H

EOX, End of System Exclusive

Note 1: MSB=0 allows LSB to control lower 128 level steps, MSB=1 allows LSB field to control upper

128 level steps. (In operation MSB=0/LSB=00 gives full mute, MSB=1/LSB=7F gives maximum

output level.)

MSB=2 places function in reduced precision mode, where LSB=00 is full mute, LSB=7F is maximum

output.

MSB=3 places function in reduced precision, reverse range mode, where LSB=7F is full mute,

LSB=00 is maximum output.

Function: Studio Level

Byte

Value Description

1

F0H

System-Exclusive Message

2

00H

1st Byte of Studio Tech ID

3

00H

2nd Byte of Studio Tech ID

4

56H

3rd Byte of Studio Tech ID

5

01H

Product ID (Model 50)

6

08H

Function: Studio Level

7

0nH

Level, MSB, range 0-3, see note 1

8

nnH

Level, LSB, range 00-7F, see note 1

9

F7H

EOX, End of System Exclusive

Note 1: MSB=0 allows LSB to control lower 128 level steps, MSB=1 allows LSB field to control upper

128 level steps. (In operation MSB=0/LSB=00 gives full mute, MSB=1/LSB=7F gives maximum

output level.)

MSB=2 places function in reduced precision mode, where LSB=00 is full mute, LSB=7F is maximum

output.

MSB=3 places function in reduced precision, reverse range mode, where LSB=7F is full mute,

LSB=00 is maximum output.