Model 50 central controller – Studio Technologies 50 2000 User Manual
Page 42

Issue 4, July 2000
Model 50/51 User Guide
Page 42
Studio Technologies, Inc.
Model 50 Central Controller
MIDI Messages to be Acted Upon
General Notes:
1. All MIDI messages to be acted upon are system-exclusive type (F0H). No channel mode,
system common, or system real time messages are utilized.
2. Studio Technologies, Inc. manufacturers ID number is 00H 00H 56H.
3. The Model 50s product device ID number is 01H.
Function: Reset to Power Up Default Configuration
Byte
Value Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
01H
Product ID (Model 50)
6
00H
Function: Restore Power Up Default Configuration
7
F7H
EOX, End of System Exclusive
Action taken after Model 50 receives MIDI message:
1. Set control room level to off.
2. Set studio level to off.
3. Set control room source to no input.
4. Set studio source to no input.
5. Set headphone source to no input.
6. Set dub source to no input.
7. Set control room outputs to off.
8. Set mono to off (stereo mode).
9. Set studio output to off.
10. Set all input levels to +4.
11. Set dub output level to +4.
12. Set dim to normal, non-dim
13. Set dim level to 20dB.
14. Set talk to studio to off.
15. Set talk to headphones to off.
16. Set slate to off.
Function: Input Level
Byte
Value Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
01H
Product ID (Model 50)
6
01H
Function: Input Level
7
0nH
Input Channel, range 1-7, 1=input 1, 2=input 2, etc.
8
0nH
Input Level, range 0-1, 0=10, 1=+4
9
F7H
EOX, End of System Exclusive