beautypg.com

Model 50 central controller – Studio Technologies 50 2000 User Manual

Page 42

background image

Issue 4, July 2000

Model 50/51 User Guide

Page 42

Studio Technologies, Inc.

Model 50 Central Controller

MIDI Messages to be Acted Upon

General Notes:

1. All MIDI messages to be acted upon are system-exclusive type (F0H). No channel mode,

system common, or system real time messages are utilized.

2. Studio Technologies, Inc. manufacturer’s ID number is 00H 00H 56H.

3. The Model 50’s product device ID number is 01H.

Function: Reset to Power Up Default Configuration

Byte

Value Description

1

F0H

System-Exclusive Message

2

00H

1st Byte of Studio Tech ID

3

00H

2nd Byte of Studio Tech ID

4

56H

3rd Byte of Studio Tech ID

5

01H

Product ID (Model 50)

6

00H

Function: Restore Power Up Default Configuration

7

F7H

EOX, End of System Exclusive

Action taken after Model 50 receives MIDI message:

1. Set control room level to off.

2. Set studio level to off.

3. Set control room source to no input.

4. Set studio source to no input.

5. Set headphone source to no input.

6. Set dub source to no input.

7. Set control room outputs to off.

8. Set mono to off (stereo mode).

9. Set studio output to off.

10. Set all input levels to +4.

11. Set dub output level to +4.

12. Set dim to normal, non-dim

13. Set dim level to 20dB.

14. Set talk to studio to off.

15. Set talk to headphones to off.

16. Set slate to off.

Function: Input Level

Byte

Value Description

1

F0H

System-Exclusive Message

2

00H

1st Byte of Studio Tech ID

3

00H

2nd Byte of Studio Tech ID

4

56H

3rd Byte of Studio Tech ID

5

01H

Product ID (Model 50)

6

01H

Function: Input Level

7

0nH

Input Channel, range 1-7, 1=input 1, 2=input 2, etc.

8

0nH

Input Level, range 0-1, 0=–10, 1=+4

9

F7H

EOX, End of System Exclusive

This manual is related to the following products: