A special function allows you to select no
input to be sent to the headphones. This
ensures a quiet feed to the phones, but
still allows the talk to phones communica-
tions function to be used. To select no
input, simply press and hold the Phones/
Studio button, then press both Communi-
cations Level buttons at the same time.
The Level buttons are located to the right
of the three Communications buttons. All
LEDs in the Phones/Studio column will be
off when no input is selected. To again
select one of the seven inputs, press and
hold the Phones/Studio button, then press
one of the seven CR/Studio buttons.
Selection of the dub source depends on
how the Model 51 has been configured.
In the default operating mode, to select
an input for dub output, press and hold
the Dub button and press one of the seven
CR/Studio buttons. The appropriate LED
in the Dub column will light. If the input is
set for mono the LED will continually flash
on and off as a warning. You can select no
input just as you did for the headphones.
Press and hold the Dub button, then press
both Level buttons at the same time.
If the dub source has been configured to
follow the control room source, each time
one of the CR/Studio buttons is pressed,
the dub source will follow. In this mode,
the Dub button is no longer active.
Control Room Outputs
Associated with the control room outputs
are three buttons and one level control.
In addition, the Communications Level
buttons are used. Use the Control Room
Level knob to set the control room output
level. There is no on/off switch. Just select
an input and turn the knob to the level you
want.
the designated input (6 or 7). When the
remote signal is no longer active, the
control room input source will return to the
previous selection.
If the studio source is configured to follow
the control room source, it will automati-
cally switch to the input you select. You
can easily tell if the studio is following the
control room because whenever the studio
output is on, the studio On LED will flash
each time you select a new input.
Selection of the headphone source de-
pends on how the Model 51 has been
configured. In the default operating mode,
to select an input for the headphones,
press and hold the Phones/Studio button
and press one of the seven CR/Studio
buttons. In the Phones/Studio column, the
LED for the input you select will light. If the
input is set for mono the LED will continu-
ally flash on and off as a warning. If the
studio source is configured to follow the
headphone source, the studio source will
automatically switch to the same input,
and, whenever the studio output is on,
the studio On LED will flash once.
If the headphone source has been config-
ured to follow the control room source,
each time one of the CR/Studio buttons
is pressed, the headphone source will
follow. You may still independently change
the headphone source by pressing the
Phones/Studio button and pressing one
of the seven CR/Studio buttons. However,
the headphone source will still follow any
changes made to the control room source.
If the studio source is configured to follow
the headphone source it will continue to
do so, even if the headphones are follow-
ing the control room; whatever source is
active for the headphones will be active
for the studio.