Install vacuum breaker flush connection, Install flushometer, Install flushometer (continued) – Sloan 136 GEM 2 Exposed Flushometer User Manual
Page 4: Flush out supply line
4
3
Install Vacuum Breaker Flush
Connection
A
Slide Spud Coupling, Nylon Slip Gasket, Rubber Gasket and Spud
Flange over Vacuum Breaker Tube.
B
Insert Tube into Fixture Spud.
C
Hand tighten Spud Coupling onto Fixture Spud.
4A
Install Flushometer
4B
Install Flushometer (Continued)
C
Align Flushometer Body and securely tighten first the Tailpiece
Coupling (1), then the Vacuum Breaker Coupling (2), and finally the
Spud Coupling (3). Use a wrench to tighten these couplings in the
order shown.
B
Align Flushometer directly above the
Vacuum Breaker Flush Connection by
sliding the Flushometer Body IN or OUT as
needed. Tighten Vacuum Breaker Coupling
by hand.
A
Lubricate tailpiece O-ring with water. Insert Adjustable Tailpiece
into Control Stop. Tighten Tailpiece Coupling by hand.
Maximum adjustment of the Sloan Adjustable Tailpiece is
1/2” (13 mm) IN or OUT from the standard 4-3/4” (121 mm)
(centerline of Flushometer to centerline of Control Stop).
If roughing-in measurement exceeds 5-1/4” (133 mm),
consult factory for longer tailpiece.
NOTE
5
Flush Out Supply Line
A
Make sure Control Stop
is CLOSED and remove
Flushometer Cover.
C
Install Flushometer Cover wrench
tight. Open Control Stop to flush
supply line. Close Control Stop
and remove Flushometer Cover.
B
Lift out Piston Assembly.
D
Reinstall Piston Assembly and
Flushometer Cover. Tighten
Flushometer Cover wrench tight.
VACUUM
BREAKER
TUBE
SPUD COUPLING
NYLON SLIP
GASKET
RUBBER
GASKET
SPUD FLANGE
VACUUM
BREAKER
TUBE
SPUD COUPLING
NYLON SLIP
GASKET
RUBBER
GASKET
SPUD FLANGE
SPUD COUPLING
NYLON
SLIP
GASKET
RUBBER
GASKET
SPUD FLANGE
MODELS 110/111,
115, 136
MODELS 120,
121, 122, 137
MODEL 180
MODEL 186
ELBOW FLUSH
CONNECTION
VACUUM
BREAKER
On valves furnished less vacuum breaker (XYV Variation) connect flush
tube to the bottom of the valve using the slip gasket supplied.
NOTE
D
If not installed, install Handle Assembly with Gasket to handle
opening on Flushometer Body. Tighten Handle Assembly securely.
VACUUM
BREAKER
COUPLING
2
ADJUSTABLE TAILPIECE
O-RING
SPUD
COUPLING
3
C/L
FIXTURE
C/L
SUPPLY
TAILPIECE COUPLING
1
FLUSHOMETER
BODY
4-3/4”
(121 mm)
±1/2”
(13 mm)
G-44 FRICTION
RING
VACUUM
BREAKER
FLUSH
CONNECTION
CONTROL
STOP
HANDLE
ASSEMBLY
GASKET
VACUUM
BREAKER
REPAIR
KIT
For high efficiency urinal flushometers (0.5, 0.25 and 0.125
gpf), it is necessary to first insert the flow control component
into the tailpiece assembly. See the H1015A flow control kit
and separate instructions for details on how to install.