3.3 Testing a Class II Appliance
•
Visually inspect the appliance and mains cord
for signs of damage.
• If the appliance passes a visual inspection
proceed with the electrical tests.
•
Plug the earth test lead into the 4mm socket
.
on the PrimeTest 100 end panel.
• Plug the appliance into the PrimeTest 100
front panel mains socket
• Connect the earth test probe to an exposed
metal part on the appliance.
• If the Appliance under test has an ON/OFF
switch, make sure it is in the ON position.
•
Press the Class II test key
• The PrimeTest 100 will now test Insulation
Resistance and Leakage current.
Note: The power switch on the appliance
under must be in the ON position to
perform an insulation test. If no
appliance is detected the PrimeTest
100 will display the following.
•
Check that the appliance power switch is in the
ON position. The test will automatically proceed
if the appliance power switch is placed in the
ON
position.
• If
the
LO LOAd enunciator remains on the
display, the load presented by the appliance
may be too small for the PrimeTest 100 to
detect. In this case, press the test key to
continue.