3.3 Testing a Class II Appliance

Visually inspect the appliance and mains cord

for signs of damage.

• If the appliance passes a visual inspection

proceed with the electrical tests.

Plug the earth test lead into the 4mm socket

.

on the PrimeTest 100 end panel.

• Plug the appliance into the PrimeTest 100

front panel mains socket

• Connect the earth test probe to an exposed

metal part on the appliance.

• If the Appliance under test has an ON/OFF

switch, make sure it is in the ON position.

Press the Class II test key

• The PrimeTest 100 will now test Insulation

Resistance and Leakage current.

Note: The power switch on the appliance

under must be in the ON position to

perform an insulation test. If no

appliance is detected the PrimeTest

100 will display the following.

Check that the appliance power switch is in the

ON position. The test will automatically proceed

if the appliance power switch is placed in the

ON

position.

• If

the

LO LOAd enunciator remains on the

display, the load presented by the appliance

may be too small for the PrimeTest 100 to

detect. In this case, press the test key to

continue.