beautypg.com

Service diagnosis – Scotsman 600 Eclipse User Manual

Page 41

background image

Service Diagnosis

Eclipse

ä 600, 800, 1000

April 2002

Page 41

Problem or Symptom

Possible Cause

Probable Correction

No ice

No power to ice making section

Restore power

No power to condensing unit

Restore power

No lights on controller

Check transformer

Unit manually switched off

Push and release the Freeze button, ask
user why it was shut off

Power to both sections, controller reset,
but condensing unit does not operate

Interconnecting control wire
disconnected, reconnect it

Low or high pressure cut outs open,
check system pressures

No water to ice making section, controller
blinking water light twice and repeating

Restore water supply, check water filters,
reset controller

Check inlet water valve operation

Check water level sensor operation,
including harness between sensor and
controller*

Ice making section has exceeded
maximum freeze time and controller has
shut down the system

Condenser coils may need cleaning

Check condenser fan blade and motor

Check for excessive air intake
temperatures at condenser coil

Check compressor contactor

Check compressor and starting
components

Check water pump

Check purge valve for leak through

Check vapor inlet valve for leak though

Ice making section has exceeded
maximum harvest time and shut down the
system

Check ice making section for lime scale
build up, clean as needed

Check condenser by pass valve

Check vapor inlet valve*

Check headmaster

Check ice sensors for cube sensing*

Check inlet water valve for leak through

Check for obstruction in ice delivery chute

Bin full light is on but bin is not full

Check ice sensors*

Check optional thermostat*

* Additional diagnostics for this component are on the following pages

This manual is related to the following products: