beautypg.com

Operational characteristics 1000 lb system – Scotsman 600 Prodigy Eclipse User Manual

Page 49

background image

Operational Characteristics 1000 lb system

Cycle Times @ Condenser Temp/Cabinet Temp/Water Temp in degrees F

System Pressures @ Condenser Temp/Cabinet Temp/Water Temp in degrees F

Headmaster maintains a minimum discharge
pressure during freeze of:

·

217 PSIG + 25, -15 PSIG

CPR Valve Setting: 55 - 60 PSIG.

Note: CPR allows a maximum low side pressure at
the CP unit’s compressor. Maximum only occurs
during harvest.

Refrigerant Charge

·

272 oz

Compressor Amps

·

Single Phase 8 to 10

·

Three Phase 5 to 7

Batch Weight: 8 lb

Discharge Pressure Cut Out Switch

·

Cuts Out at: 450 PSIG

·

Resets at: 350 PSIG

Prodigy Eclipse

ä 600, 800, 1000

February 2008

Page 49

70/70/50

90/90/70

120/110/100

Freeze

6 to 8 minutes

8 to 10 minutes

16 to 18 minutes

Harvest

1 to 1.5 minutes

1 to .5 minutes

.5 to 1 minutes

70/70/50

90/90/70

120/110/100

Suction at Ice Making Section, end of Freeze

26 to 31 PSIG

27 to 32 PSIG

30 to 35 PSIG

Suction at Ice Making Section, Harvest

85 to 105 PSIG

90 to 110 PSIG

140 to 160 PSIG

Discharge at Condensing Unit: Freeze - 5 minutes in

230 to 250 PSIG

230 to 250 PSIG

345 to 365 PSIG