Use and Operation

Once started, the ice machine will automatically
make ice until the bin or dispenser is full of ice.
When ice level drops, the ice machine will resume
making ice.

Caution: Do not place anything on top of the ice
machine, including the ice scoop. Debris and
moisture from objects on top of the machine can
work their way into the cabinet and cause serious
damage. Damage caused by foreign material is not
covered by warranty.

There are four indicator lights at the front of the
machine that provide information on the condition
of the machine.

Indicator Lights:

·

Power

·

Status

·

Water

De-scale & Sanitize

Indicator Lights & Their Meanings

Power

Status

Water

De-Scale & Sanitize

Steady Green

Normal

Normal – bin full or making ice

-

-

Blinking Green

Self Test
Failure

Switching on or off

-

-

Blinking Red

-

Diagnostic shutdown or, if making ice,
temperature sensor failure

Lack of
water

-

Yellow

-

-

-

Time to de-scale and
sanitize

Blinking Yellow

-

-

-

In Cleaning mode

Light off

No power

Switched off

Normal

Normal

All Blinking

Unit remotely locked out – check with leasing company

If the Water light is on, the machine has sensed a
lack of water. Check the water supply to the
machine. The water could have been shut off or
the water filter cartridges might need to be
changed.

If the De-Scale light is on, the machine has
determined that it needs to be cleaned. Contact an
authorized Scotsman service agent and have the
machine cleaned, de-scaled and sanitized.

Prodigy Eclipse

ä 600, 800, 1000

February 2008

Page 31

Note: A Component Indicator Light switches ON to
indicate that the component is operating.

Note: There are two Curtain Switch lights, SW1 and
SW2. These single plate models have one curtain
switch light on all the time, as a curtain switch light
is ON when a curtain is either open or not present.