Service Diagnosis

Prodigy Eclipse

ä 600, 800, 1000

February 2008

Page 44

Problem or Symptom

Possible Cause

Probable Correction

No ice

No power to ice making section

Restore power

No power to condensing unit

Restore power

No lights on controller

Check transformer

Unit manually switched off

Push and release the On button, ask user
why it was shut off

Power to both sections, controller reset,
but condensing unit does not operate

Interconnecting control wire
disconnected, reconnect it

Low or high pressure cut outs open,
check system pressures

No power to compressor contactor coil.

Check toggle switch in CP.

Check EH222 compressor relay.

No water to ice making section, controller
blinking water light

Restore water supply, check water filters,
reset controller

Check inlet water valve operation

Check water level sensor

Ice making section has exceeded
maximum freeze time and controller has
shut down the system

Condenser coils may need cleaning

Check condenser fan blade and motor

Check for excessive air intake
temperatures at condenser coil

Check compressor contactor

Check compressor and starting
components

Check water pump

Check purge valve for leak through

Check vapor inlet valve for leak though

Ice making section has exceeded
maximum harvest time and shut down the
system

Check ice making section for lime scale
build up, clean as needed

Check condenser by pass valve

Check vapor inlet valve*

Check headmaster

Check curtain switch

Check inlet water valve for leak through

Check for obstruction in ice delivery chute

CP solenoids do not activate during
harvest

Check solenoid relay in EH222

Bin full code displayed but bin is not full

Check curtain switch

Check optional thermostat*

* Additional diagnostics for this component are on the following pages