Configuration

A remote low side cuber system includes several
sub systems: an ice making section, a remote
compressor package, and a remote air cooled
condenser. Additionally, there are several models
of each sub-system and this manual covers all of
them.

The ice making sections are designed for use
indoors in a controlled environment. The remote
compressor packages and condensers are
designed to operate outdoors. Each sub-system
has limits for power, water and temperature.

Operational Limitations:

Minimum

Maximum

Air Temp (IMS)

50

o

F

100

o

F.

Air Temp (CU)

-20

o

F.

120

o

F.

Water Temp

40

o

F.

100

o

F.

Water Pressure

20 psi

80 psi

Voltage (IMS)

104

126

Voltage (CU)

198

253

IMS = Ice Making Section, CU= Condensing Unit

Do Not operate the machine in conditions beyond
these limitations. Doing so will void the warranty.

Scotsman ice systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of UL and NSF.

Scotsman assumes no liability of responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any part and/or other components not
specifically approved by Scotsman.

Scotsman reserves the right to make design
changes and/or improvements at any time.

Specifications and design are subject to change
without notice.

Warranty

Refer to the warranty coverage in effect when the
equipment was sold. Warranty statements are
included with each product.

Systems:

Each sub-system is a separate entity that carries
its own model and serial number. They must be
combined to create a remote cuber low side
system.

Prodigy Eclipse

ä 600, 800, 1000

February 2008

Page 2

System Size

Condensing Unit (CU)

Ice Making Section (IMS)

Compressor Package

Condenser

Model

Electrical

Model*

Electrical

Model

Electrical

600**

C0600CP-32A

208-230/60/1

ERC680-32A

208-230/60/1

EH222SL-1

115/60/1

800

C0800CP-32A

208-230/60/1

ERC680-32A

208-230/60/1

EH222SL-1 OR
EH222ML-1

115/60/1

C0800CP-3A

208-230/60/3

1000

C1410CP-32A

208-230/60/1

ERC1086-32A 208-230/60/1

EH222SL-1 OR
EH222ML-1

115/60/1

C1410CP-3A

208-230/60/3

Notes: Voltage Codes are at the end of the model
number. Codes read Voltage/Hertz/Phase. Those
related to these products include:

-1 = 115/60/1

-3 = 208-230/60/3

-32 = 208-230/60/1

System Information

*ER2C6810-32 is a two circuit remote condenser
and can be used with any combination of a 600 or
800 or 1000 system.

** Do NOT use EH222ML in 600 size systems.

Pre-charged tubing kits are required to
interconnect the IMS to the CP.

Interconnecting 24 volt control wire ships with the
CP unit.