Scotsman 600 Prodigy Eclipse User Manual
Page 41

7
Allow the ice machine cleaner / scale remover
to circulate in the water system for at least 10
minutes.
8
Push and release the Clean button again.
The yellow Clean light will be on continuously
and the machine will drain and refill the
reservoir to flush out the ice machine cleaner
and residue.
9
Allow the drain and refill process to continue
for at least 20 minutes.
10
Push and release the Off button. The clean
cycle will stop and the display will show O.
Note: If unit has not been de-scaled for an
extended period of time and significant mineral
scale remains, repeat steps 5 - 10.
11
Mix a cleaning solution of 1 oz of ice machine
cleaner to 12 ounces of water.
12
Remove curtain from unit.
13
Locate ice thickness sensor. Squeeze
mounting legs together to release sensor.
14
Remove water distributor from ice machine by
disconnecting its hose, squeezing the
retaining snaps together and pushing the
distributor to the right as far as possible. Lift
up to remove. Inspect distributor for restricted
orifice holes. Be sure all holes are full open.
15
Locate water level sensor. Squeeze catches
together and pull up to remove sensor.
16
Wash the metal surfaces of the ice thickness
sensor and the adjustment screw with ice
machine cleaner solution. Also wash the
water distributor, water level sensor probes
and curtain with the ice machine cleaner
solution.
17
Mix a solution of locally approved sanitizer.
Note; A possible sanitizing solution may be made
by mixing 1 ounce of liquid household bleach with
2 gallons of warm (95-115
o
F.) potable water.
Prodigy Eclipse
ä 600, 800, 1000
February 2008
Page 41
Remove Water Distributor
Inspect Orifice Holes
Inspect Water Distributor
Remove Ice Thickness Sensor