beautypg.com

Operational characteristics 800 lb system – Scotsman 600 Prodigy Eclipse User Manual

Page 48

background image

Operational Characteristics 800 lb system

Cycle Times @ Condenser Temp/Cabinet Temp/Water Temp in degrees F.

System Pressures @ Condenser Temp/Cabinet Temp/Water Temp in degrees F

Headmaster maintains a minimum discharge
pressure during freeze of:

·

217 PSIG + 25, -15 PSIG

CPR Valve Setting: 55 - 60 PSIG.

Note: CPR allows a maximum low side pressure at
the CP unit’s compressor. Maximum only occurs
during harvest.

Refrigerant Charge

·

232 oz

Compressor Amps

·

Single Phase - 6 to 8

·

Three Phase - 5 to 7

Batch Weight: 8 lb

Discharge Pressure Cut Out Switch

·

Cuts Out at: 450 PSIG

·

Resets at: 350 PSIG

Prodigy Eclipse

ä 600, 800, 1000

February 2008

Page 48

70/70/50

90/90/70

120/110/100

Freeze

10 to 12 minutes

13 to 15 minutes

19 to 21 minutes

Harvest

1 to 1.5 minutes

1 to 1.5 minutes

.5 to 1 minute

70/70/50

90/90/70

120/110/100

Suction at Ice Making Section, end of Freeze

26 to 31 PSIG

26 to 31 PSIG

30 to 35 PSIG

Suction at Ice Making Section, Harvest - Peak

85 to 105 PSIG

105 to 125 PSIG

140 t0 160 PSIG

Discharge at Condensing Unit: Freeze - 5 minutes in

230 to 250 PSIG

250 to 270 PSIG

330 to 350 PSIG