Water and Drain
Right Draining:
1. Connect ¾” PVC to the female PVC fitting. If
copper is required by code, remove the PVC
connector and install a ¾” FPT female copper
fitting onto the ¾” NPT male fitting. Do all soldering
before connecting to the male fitting.
2. In tight locations do the next step after the unit is
placed on the dispenser or bin.
3. Connect rigid drain tubing to the reservoir drain
tube. Route the drain either out the back, under the
unit (through the notch in the base) to the left side
or to the right side. A vent is built into the unit,
so no external vent is required.
Run the drain tubing to the building drain. Do not
“Tee” into any other drain, including the bin or
dispenser drain.